Vertiv Liebert ITA2 10kVA Rack 0MIN autonomy

SKU
ITA2101A0000A00
Login for pricing
10kVA, 173 - 498 V, 40 - 70 Hz, 10 kW, 0.99 kW/kVA
More Information
SKU ITA2101A0000A00
EAN 0767041023732
Manufacturer Vertiv
Product Family Liebert
PDF URLs View PDF
With a unity output power factor, Liebert® ITA2 perfectly matches the needs of modern IT loads, and with its wide input voltage and frequency range it effectively reduces the need for battery intervention, thus prolonging battery life. Liebert® ITA2 offers enhanced flexibility with a wide range of accessories for both stand-alone and rack-mount installations. When rack mounted, it allows to install up to 20 kVA in just 3U of space, achieving a remarkable space saving.

- Rack-tower design for installation flexibility
- Double conversion efficiency up to 96.2%
- Ultra high power density
- Unity output power factor
- Able to deliver both three-phase and single-phase output
- 0.99 input power factor for better grid or generator compatibility
Power
Output frequency regulation50/60 Hz
Output power10000 W
Input operation voltage (min)173 V
Input operation voltage (max)498 V
Output operation voltage (min)380 V
Output operation voltage (max)415 V
Maximum current13 A
Efficiency96.2%
Output voltage Total Harmonic Distortion (THD)2%
Input current Total Harmonic Distortion (THD)3%
Output power capacity10 kVA
Performance
UPS topologyDouble-conversion (Online)
Number of output phases3
Number of input phases3
Noise level58 dB
Overload capacity (1 minute)150%
Features
UPS topologyDouble-conversion (Online)
Output frequency regulation50/60 Hz
Number of output phases3
Number of input phases3
Output power10000 W
Input operation voltage (min)173 V
Input operation voltage (max)498 V
Output operation voltage (min)380 V
Output operation voltage (max)415 V
Maximum current13 A
Efficiency96.2%
Output voltage Total Harmonic Distortion (THD)2%
Noise level58 dB
Input current Total Harmonic Distortion (THD)3%
Output power capacity10 kVA
Overload capacity (1 minute)150%
Input frequency40 - 70 Hz
Design
International Protection (IP) codeIP20
Form factorRackmount/Tower
Product colourBlack
CertificationEN/IEC/AS 62040-2 VFI-SS-111 EN/IEC/AS 62040-1
Technical details
BypassBypass voltage tolerance (%) selectable from +20 to -40 Bypass frequency tolerance (%) ±20 (±10 selectable)
Certificates
CertificationEN/IEC/AS 62040-2 VFI-SS-111 EN/IEC/AS 62040-1
Weight & dimensions
Weight23 kg
Width430 mm
Height130 mm
Depth500 mm
Other features
BypassBypass voltage tolerance (%) selectable from +20 to -40 Bypass frequency tolerance (%) ±20 (±10 selectable)